1.8 Technical Details
No of Injectors 1
Gas Connection ½” N.P.T
Electrical Supply 120 volt 1 phase 60Hz
Vent size (in) 4” or 6” (101mm or 152mm)
Unitary Fan Motor Details 120 volt 1 phase 60Hz
Current Rating 1.2A MAX
Ignition Electronic Program Start up with Spark Ignition
Thermostat 24Vac 60Hz 1.5A Max. total load
MODEL
Natural Gas LP Gas
Min. Heater
Length
Max. Heater
Length
Min. Heater
Length
Max. Heater
Length
High / Low
Rate BTU/Hr
High / Low
Rate BTU/Hr
S ft (m) S ft (m) U (ft) U (ft)
60
60,000/45,000 60,000/45,000
20 (6.1) 40 (12.1) 20 (6.1) 40 (12.1)
80
80,000/60,000 80,000/60,000
30 (9.1) 40 (12.1) 40 (12.1) 40 (12.1)
100
100,000/65,000 100,000/65,000
30 (9.1) 40 (12.1) 40 (12.1) 40 (12.1)
125
123,500/95,000 125,000/95,000
30 (9.1) 50 (15.2) 40 (12.1) 40 (12.1)
150
150,000/100,000 150,000/100,000
40 (12.1) 60 (18.3) 40 (12.1) 60 (18.3)
170
169,000/125,000 169,000/125,000
50 (15.2) 70 (21.3) 60 (18.3) 60 (18.3)
200
200,000/150,000
N/A
50 (15.2) 70 (21.3) 60 (18.3) 60 (18.3)
Appliances can be installed up to 10,000 ft in the USA. Altitude conversion kits are available on request.
Natural Gas 0- 2000 ft (0-610m) USA
Size
60 80 100 125 150 170 200
“WC Hi
4.2 3.9 4.9 4.5 4.4 4.0 3.5
“WC Lo
2.4 2.3 2.1 2.7 2.2 2.4 2.2
LP Gas 0- 2000 ft (0-610m) USA
Size
60 80 100 125 150 170 200
“WC Hi
6.1 5.2 8.2 7.6 7.2 6.8 N/A
“WC Lo
3.5 3.0 3.7 4.4 3.3 3.9 N/A
Natural Gas 2001- 4000 ft (611-1220m) USA
Size
60 80 100 125 150 170 200
“WC Hi
4.1 3.7 4.7 4.3 4.2 3.8 3.3
“WC Lo
2.3 2.1 2.0 2.5 2.0 2.2 2.0
USA LP Gas 2001- 4000 ft (611-1220m)
Size
60 80 100 125 150 170 200
“WC Hi
6.0 5.0 8.0 7.4 7.0 N/A
“WC Lo
3.4 2.9 3.5 4.2 3.1 N/A
Natural Gas 0- 2000 ft (0-610m) CANADA
Size
60 80 100 125 150 170 200
“WC Hi
4.2 3.9 4.9 4.5 4.4 4.0 3.5
“WC Lo
2.4 2.3 2.1 2.7 2.2 2.4 2.2
LP Gas 0- 2000 ft (0-610m) CANADA
Size
60 80 100 125 150 170 200
“WC Hi
6.1 5.2 8.2 7.6 7.2 6.8 N/A
“WC Lo
3.5 3.0 3.7 4.4 3.3 3.9 N/A
Natural Gas 2001- 4500 ft (611-1370m) CANADA
Size
60 80 100 125 150 170 200
“WC Hi
4.1 3.7 4.7 4.3 4.2 3.8 3.3
“WC Lo
2.3 2.1 2.0 2.5 2.0 2.2 2.0
CANADA LP Gas 2001- 4500 ft (611-1370m)
Size
60 80 100 125 150 170 200
“WC Hi
6.0 5.0 8.0 7.4 7.0 N/A
“WC Lo
3.4 2.9 3.5 4.2 3.1 N/A