Reznor YDSA Unit Installation Manual Manual de usuario

Busca en linea o descarga Manual de usuario para Radiadores Reznor YDSA Unit Installation Manual. Reznor YDSA Unit Installation Manual User Manual [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Form I-Y, P/N 273646R6, Page 1
Installation / Operation
Applies to: Models YDHA, YDMA, and YDSA
Packaged Rooftop Equipment
!
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or
property damage.
Be sure to read and understand the installation, operation, and service instructions in
this manual.
Improper installation, adjustment, alteration, service, or maintenance can cause
serious injury, death, or property damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a phone remote from the building. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency,
or the gas supplier.
R-410A
Refrigerant
A
G
E
N
C
Y
P
R
O
C
E
S
S
S
T
A
R
T
-
U
P
P
R
O
D
U
C
T
C
U
S
T
O
M
E
R
W
A
R
R
A
N
T
Y
C
O
N
V
E
R
G
E
N
T
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
CQS
CQS
DANGER:
This unit contains R-410A high pressure refrigerant. Hazards exist that could result in
personal injury or death. Installation, maintenance, and service should only be performed by
an HVAC technician qualied in R-410A refrigerant and using proper tools and equipment.
Due to much higher pressure of R-410A refrigerant, DO NOT USE service equipment or
tools designed for R22 refrigerant.
Form I-Y (Version .5)
Obsoletes I-Y (Version .4)
Vista de pagina 0
1 2 3 4 5 6 ... 75 76

Indice de contenidos

Pagina 1 - WARNING:

Form I-Y, P/N 273646R6, Page 1Installation / OperationApplies to: Models YDHA, YDMA, and YDSA Packaged Rooftop Equipment!WARNING:FIRE OR EXPLOSION HA

Pagina 2 - 1.0 General

Form I-Y, P/N 273646R6, Page 105.0 Mounting5.1 Unit WeightsFor unit weights and or corner weights, refer to www.ReznorHVAC.com or call 1-800-695-1901.

Pagina 3 - 1.4 Installation

Form I-Y, P/N 273646R6, Page 115.3.1 Down ow Roof Curbs Both Option CJ31 and CJ34 are 16" (406mm) high roof curbs designed for vertical (down) d

Pagina 4

Form I-Y, P/N 273646R6, Page 12ItemDescriptionOption CJ31 Option CJ34Cabinet 1 Cabinet 2 Cabinet 3 Cabinet 1 Cabinet 2 Cabinet 3Package P/N 272399 272

Pagina 5 - Controls Options:

Form I-Y, P/N 273646R6, Page 13Installation Instructions for Down Discharge Roof Curbs, Option CJ31 and Option CJ34 1. Refer to FIGURE 6 shown on page

Pagina 6 - 4.0 Clearances and Dimensions

Form I-Y, P/N 273646R6, Page 145.3.2 Curbs for Horizontal AirowOptions CJ48 and CJ55 are 36" (914mm) high roof curbs designed for horizontal dis

Pagina 7 - 4.2 Dimensions

Form I-Y, P/N 273646R6, Page 15Hardware in Options CJ48 & CJ55Qty P/N Description Use12 16243 Lag ScrewFor top level screws (1 each corner; 4 each

Pagina 8 - 4.2 Dimensions (cont’d)

Form I-Y, P/N 273646R6, Page 16Installation Instructions for Cabinet Sizes 1 & 2 Horizontal Airow Roof Curbs, Option CJ48 and Option CJ551. Refer

Pagina 9 - Side View

Form I-Y, P/N 273646R6, Page 17Lag Screw P/N 16243Lock Washer P/N 1333(Qty 12 each)Wood nailer side - screw head towards panelSheetmetal Screw P/N 118

Pagina 10 - 5.0 Mounting

Form I-Y, P/N 273646R6, Page 185.3 Mounting on a Roof Curb (cont'd) 5.0 Mounting (cont'd)5.3.2 Curbs for Horizontal Airow (cont’d)Installat

Pagina 11 - (Inlet Hood End)

Form I-Y, P/N 273646R6, Page 195.4 Rigging and LiftingDANGERIf there is any visible damage or any question about the integrity of a lifting point, DO

Pagina 12 - 5.0 Mounting (cont'd)

Form I-Y, P/N 273646R6, Page 21.1 Cautions and WarningsThere are warning labels on the unit, on the front page, and throughout this manual. For your s

Pagina 13 - Roof Curb

Form I-Y, P/N 273646R6, Page 20DANGERTo prevent death, injury, or equipment damage caused by inadequate or improper rigging, test lift the unit be

Pagina 14

Form I-Y, P/N 273646R6, Page 216.1.2 30% Inlet Air Hood in Inlet Air Conguration Option AR71a) Remove screwin cabinet top. Hood Top(edge must go und

Pagina 15

Form I-Y, P/N 273646R6, Page 226.2 Duct Connections and Duct work Requirements and Suggestions for Installing DuctsDuct connections are in the roof cu

Pagina 16 - Option CJ55

Form I-Y, P/N 273646R6, Page 23All electrical wiring and connections including electrical grounding MUST be made in accordance with the National Elect

Pagina 17 - Supply Air

Form I-Y, P/N 273646R6, Page 24FIGURE 17A - Disconnect Switch Wiring ConnectionsField-supplied or Option CP Disconnect SwitchField-supplied or Option

Pagina 18

Form I-Y, P/N 273646R6, Page 257.2.3 3-phase Wiring Check3-Phase Wiring Connection - There is a chance of unknowingly connecting 3-phase power in s

Pagina 19 - 5.4 Rigging and

Form I-Y, P/N 273646R6, Page 267.4 Electrical Compartment - Control LocationsOptionalLow AmbientController- ECM Condenser FanOptionalLow AmbientContro

Pagina 20 - 6.0 Mechanical

Form I-Y, P/N 273646R6, Page 277.5 Control Wiring7.5.1 Digital Controller and DisplaysCarel Programmable Digital Controller (in the control compartmen

Pagina 21 - 3 49.39 / 1255

Form I-Y, P/N 273646R6, Page 287.5.2 Sensor Wiring 24V Field Control Wiring Length and Size RequirementsTotal Wire Length Minimum Recommended Wire Siz

Pagina 22 - 6.0 Mechanical (cont’d)

Form I-Y, P/N 273646R6, Page 29ID1ID2IDC1ID3ID4ID5ID6ID715ID8CONTACTSCALL FOR DEHUMIDIFICATIONJ515PRPRFACTORY INSTALLED OCCUPIED JUMPER -- REMOVE JUMP

Pagina 23 - 7.0 Electrical and

Form I-Y, P/N 273646R6, Page 3WARNING Gas-red appliances are not designed for use in hazardous atmospheres containing ammable vapors or

Pagina 24 - 7.2 Supply Wiring (cont’d)

Form I-Y, P/N 273646R6, Page 30Option BE17 • Field Installed in the supply air duct• Smoke Detector, P/N 159553, Sampling Tube, P/N 259069Wiring Con

Pagina 25

Form I-Y, P/N 273646R6, Page 317.6 Supply Fan with Variable Frequency Drive Variable Frequency DriveThe supply fan is a plenum fan with backward curve

Pagina 26 - Electrical Compartment

Form I-Y, P/N 273646R6, Page 32Optional Hot Gas Bypass ValveCheck Hot Gas Bypass Valve Setting - On the circuit with a hot gas bypass valve, connect a

Pagina 27 - • Allows same access as

Form I-Y, P/N 273646R6, Page 338.2 Supply Fan ControlThe main controller is programmed to control the fan to operate the unit in two modes: Occupied a

Pagina 28 - • Shipped with the unit for

Form I-Y, P/N 273646R6, Page 34Pickup Tube for Duct work, Option VFC3, P/N 2348212. Pickup Tube Locations Duct Static (Option VFC3) Pickup Tubes - M

Pagina 29 - (cont’d)

Form I-Y, P/N 273646R6, Page 35Optional Equipment (alphabetically listed) ...Where to Look Electric Heat Section (Optio

Pagina 30 - • P/N 42782

Form I-Y, P/N 273646R6, Page 36Outside Air Only Dampers, Option AR8, AR2D, AR2L, or AR2Y - The damper motor is electrically interlocked with the blowe

Pagina 31 - Compressor Amps/

Form I-Y, P/N 273646R6, Page 379.1.3 Energy Recovery Wheel, Option EW__The energy recovery wheel rotates through both the inlet and exhaust airstreams

Pagina 32 - 8.0 Controls

Form I-Y, P/N 273646R6, Page 38Sizing Gas Supply LinesCapacity of PipingCubic Feet per Hour based on 0.3" iwc Pressure DropSpecic Gravity for Na

Pagina 33 - Controller

Form I-Y, P/N 273646R6, Page 39FIGURE 23 - Manifolds with Staged Control Option AG71 (2-stage control, single heat section) and Option AG72 (4-stage c

Pagina 34 - 8.0 Controls (cont'd)

Form I-Y, P/N 273646R6, Page 4This system was test operated and inspected at the factory and was in operating condition. If the equipment has incurred

Pagina 35 - Sections

Form I-Y, P/N 273646R6, Page 40Instructions for Measuring Manifold Pressure - Option AG71 (2-stage with one heat section)Gas Pressure Tap LocationLoca

Pagina 36 - Option PE__

Form I-Y, P/N 273646R6, Page 41Manifold Pressure Tap LocationsLocate the 1/8” pressure taps on both manifolds. (See FIGURE 23, page 39). Both high-

Pagina 37 - 9.2 Gas Heat

Form I-Y, P/N 273646R6, Page 42Step 4 - Low Fire Manifold Pressure Adjustment Heat Section 1Remove the cap from the low re adjustment screw on the tw

Pagina 38 - 9.2 Gas Heat Section (cont’d)

Form I-Y, P/N 273646R6, Page 43NOTE: The manifolds illustrated are for standard efciency, non-condensing heat sections. Follow the same steps for mea

Pagina 39 - Manifold Pressure Tap

Form I-Y, P/N 273646R6, Page 44Gas Pressure Tap LocationLocate the 1/8” pressure tap on the manifold (See FIGURE 24A, page 43). With the manual valve

Pagina 40

Form I-Y, P/N 273646R6, Page 45Step 4 Modulating Valve Adjustment Instructions (See FIGURE 24B, page 43) - HIGH FIRE SETTING (BUTTON #1)1. To enter th

Pagina 41

Form I-Y, P/N 273646R6, Page 46Gas Pressure Tap LocationLocate the 1/8” pressure taps on both manifolds. (See FIGURE 24B, page 43). Both high-re and

Pagina 42

Form I-Y, P/N 273646R6, Page 47Step 4 Modulating Valve Adjustment Instructions (See FIGURE 24B, page 43) - HIGH FIRE SETTING (BUTTON #1)1. To enter th

Pagina 43 - Pressure Switch

Form I-Y, P/N 273646R6, Page 48If no adjustment is required, proceed to Step 8.If an adjustment is required, proceed to Step 7.Step 7 - High Fire Mani

Pagina 44

Form I-Y, P/N 273646R6, Page 49Manifold Pressure Settings (iwc) by Gas Control Option and Type of GasHeat SizeInput (Btuh)Full Rate (high re)Outlet

Pagina 45

Form I-Y, P/N 273646R6, Page 5Controls Options:Option PN DescriptionCabinet Size / Option Availability1 (a) 2 3CL23 257338 24v 2-stage heating/cool

Pagina 46

Form I-Y, P/N 273646R6, Page 50BTUH Inputs and Capacities by Altitude in the United StatesAltitudeNormal InputThermal Output Capacity2-Stage Minimum I

Pagina 47

Form I-Y, P/N 273646R6, Page 51Gas Pressure Safety Switches, Option BP4See Manifold illustrations, FIGURE 23, page 39, or FIGURE 24A, page 43.The opti

Pagina 48

Form I-Y, P/N 273646R6, Page 529.2.3 Heat Section ControlsThe ignition sequence depends on whether the heat section has staged control (YDSA only) or

Pagina 49

Form I-Y, P/N 273646R6, Page 53DSI Control Module LED Flash CodesFlash Code DescriptionFast Flash Normal operationSteady OFF No power, blown fuse, or

Pagina 50

Form I-Y, P/N 273646R6, Page 549.2 Gas Heat Section (cont’d)DANGERSafe operation requires proper venting ow. Never bypass the combustion air

Pagina 51 - Switches, Option BP4

Form I-Y, P/N 273646R6, Page 55* Heat sections with dual furnaces. When only one size is listed, both furnaces are the same size and two identical hig

Pagina 52

Form I-Y, P/N 273646R6, Page 56High Efciency Heat Section Condensate DrainA unit with a high efciency, condensing gas heat section requires a conden

Pagina 53

Form I-Y, P/N 273646R6, Page 57Freeze Resistant Trap, P/N 271064, is shipped with the unit to be installed in the condensate drain. It is mandatory th

Pagina 54 - Section

Form I-Y, P/N 273646R6, Page 58FIGURE 29B - Condensate Drain Trap for High-Efciency Heat Section DrainTrap Installation: Install the trap as shown in

Pagina 55 - Condenser

Form I-Y, P/N 273646R6, Page 5910.2 Checklist Prior to StartupAssumptions: All connections are made; actual startup is imminent. Site is clean; all ex

Pagina 56

Form I-Y, P/N 273646R6, Page 63.3 StorageIf this system is going to be stored, take precautions to prevent condensate formation inside the electrical

Pagina 57 - Vent(s)

Form I-Y, P/N 273646R6, Page 60 Check that combustion air inlet and ue discharge openings are free of obstructions. If installed in California, ver

Pagina 58 - 9.3 Electric Heat

Form I-Y, P/N 273646R6, Page 615. Use the up or down arrow keys to navigate to the a.Test Mode menu and press the enter key to select. 6. From the tes

Pagina 59 - Startup:

Form I-Y, P/N 273646R6, Page 6210. Instructions for Setting Fans to Test and Balance Airow Adjusting the unit fan speeds to achieve the desired air-

Pagina 60 - Alarm Prg Esc Up Enter Down

Form I-Y, P/N 273646R6, Page 6314. Electric Heat Only - From Test Mode Screen E.a.5, press the enter key until the cursor is ashing on the Heat Capac

Pagina 61 - (continued)

Form I-Y, P/N 273646R6, Page 6417. Saving Maximum Fan Speed Values Adjusted in Step 10 Press the escape key to return to the service menu and navigat

Pagina 62 - Balance Airow

Form I-Y, P/N 273646R6, Page 6510.4.2 Setting the Unit for Operation via the Digital Input Closure or Time Schedule - Option D21 From the Main Menu,

Pagina 63

Form I-Y, P/N 273646R6, Page 66Power Supply Voltage PhasingIMPORTANT: All refrigeration checks must be made by a qualied R-410A refrigeration technic

Pagina 64 - 10.4 Other Control Settings

Form I-Y, P/N 273646R6, Page 67DANGERThe gas burner in the optional gas-red heat section is designed to provide safe, complete combustion. However,

Pagina 65

Form I-Y, P/N 273646R6, Page 68AppendixCabinet Size 1, 2 or 3 by Model and Model Size Cross-Referenced to Heat Section Size and TypeModel YDHA YDMA YD

Pagina 66 - 10.5 Checklist

Form I-Y, P/N 273646R6, Page 69BE18 Dirty Filter Pressure Switch for Main Filters only FactoryBE22 Relay for Remote Exhaust Fan Start/Stop FactoryOpti

Pagina 67

Form I-Y, P/N 273646R6, Page 7Models and Cooling SizesCabinet SizeSystem without Energy Recovery Wheel System with Optional Energy Recovery WheelA1 B

Pagina 68 - Size and Type

Form I-Y, P/N 273646R6, Page 70Static Pressure (iwc)Supply Fan Airow (cfm) - by Model and SizeStatic Pressure (iwc)YDSA YDHA YDMA120 150 180 210 60 9

Pagina 69 - Appendix (cont’d)

Form I-Y, P/N 273646R6, Page 71PE4 Airow (cfm) / Pressure Drop (iwc) Tables by Fan and Unit SizeStatic Pressure (iwc)Power Exhaust PE4 Airow (cfm) -

Pagina 70

Form I-Y, P/N 273646R6, Page 72PE5 Airow (cfm) / Pressure Drop (iwc) Tables by Fan and Unit SizeStatic Pressure (iwc)Power Exhaust PE5 Airow (cfm) b

Pagina 71

Form I-Y, P/N 273646R6, Page 73PE6 Airow (cfm) / Pressure Drop (iwc) Tables by Fan and Unit SizeAppendix (cont’d)Static Pressure (iwc)Power Exhaust P

Pagina 72

Form I-Y, P/N 273646R6, Page 74Start-Up Information FormApplies to: Models YDHA, YDMA, and YDSASTARTUP FORMJob NameContractor Verify shipping bracket

Pagina 73

Form I-Y, P/N 273646R6, Page 75(Catalogs and instruction manuals are available at www.ReznorHVAC.com.)Airow Pressure Drops ...

Pagina 74 - Start-Up Information Form

Form I-Y, P/N 273646R6, Page 76Installer: Name ________________________________________________________ Company _________________________________

Pagina 75 - References

Form I-Y, P/N 273646R6, Page 8OptionalOutsideAir HoodAirflowHood66-1/2(1689)B - Inside the Curb CapA - Base Length51-11/16 (1313) - Inside the Curb Ca

Pagina 76 - I) Form I-Y (Version .5)

Form I-Y, P/N 273646R6, Page 9Bottom View showing Duct OpeningsXY55-5/64(1399)62-1/64(1575)**Optional Disconnect Switch**Power Supply12-5/64(307)Gas I

Comentarios a estos manuales

Sin comentarios