IMPORTANT NOTES:
• Allgaspipingmustbeinstalledincompliancewith
localcodesandutilityregulations.Intheabsence
oflocalcodesthegaslineinstallationmustcomply
withthelatesteditionoftheNationalFuelGasCode
ANSI Z223.1 or CAN/CGA B149 Installation Codes.
• Somelocalcodesrequiretheinstallationofamanual
mainshut-offvalveandgroundjointunionexternal
tothefurnace.Theshut-offvalveshouldbereadily
accessibleforserviceand/oremergencyuseSee
Figure9(page12).Consultthelocalutilityorgas
supplier for additional requirements regarding
placementofthemanualmaingasshut-off.
• Gaspipingmustneverruninorthroughairducts,
chimneys,gasvents,orelevatorshafts.
• Compoundsusedtosealjointsongaspipingmust
beresistanttotheactionsofLPpropanegas.
• Themaingasvalveandmainpowerdisconnectto
thefurnacemustbeproperlylabeledbytheinstaller
incaseemergencyshutdownisrequired.
• An1/8inchNPTpluggedtapmustbeinstalledin
thegaslineimmediatelyupstreamofthegassupply
connectiontothefurnaceforusewhenmeasuring
thegassupplypressure.Theplugshouldbereadily
accessibleforserviceuse.
• Adriplegshouldbeinstalledintheverticalpipe
runtotheunit(Figure9).
This unit is shipped from the factory for natural gas
operation at sea level elevation and is equipped with a
#36 orifice at each burner. Table 14 (page 40), lists gas
pipe capacities for standard pipe sizes as a function of
length in typical applications based on nominal pressure
drop in the line.
This unit only has right side gas entry. When connecting
the gas, provide clearance between the gas supply line
and the entry hole in the unit’s casing to avoid unwanted
noise and/or damage to the unit. A typical gas service
hookup is shown in Figure 9 (page 12).
LeakCheck
After the gas piping to the unit is complete, all connections
must be tested for gas leaks. This includes pipe connections
at the main gas valve, emergency shutoff valve and other
gas connectors.
The soap and water solution can be applied on each
joint or union using a small paintbrush. If any bubbling is
observed, the connection is not sealed adequately and
must be retightened. Repeat the tightening and soap
check process until bubbling ceases.
IMPORTANT NOTES:
• Ifpressuretestingthegassupplylinesatpressures
greaterthan1/2psig(14inchesWC),theunitmust
bedisconnectedfromthegassupplypipingsystem
topreventdamagetothegasvalve.
• Ifthetestpressureislessthanorequalto1/2psig
(14inchesWC),theunitmustbeisolatedfromthe
gassupplylinebyclosingthemanualshut-offvalve.
HighAltitudeDeration
High altitude application with this unit depends on the
installation altitude and the heating value of the gas. At
high altitudes, the heating value of natural gas is always
lower than the heating value at sea level.
All installations of this equipment must be made in
accordancewiththeNationalFuelGasCodeorwithlocal
jurisdiction codes. For installations at exactly 2,000 feet
in altitude or under, the installer does not need to derate
the heat exchanger performance. For any installation that
exceeds 2,000 feet, please see the following instructions
andexample:
WARNING:
Thereductionofinputratingnecessaryforhigh
altitudeinstallationmayonlybeaccomplished
withfactorysuppliedorices.Donotattemptto
drilloutoricesintheeld.Improperlydrilled
orices may cause re, explosion, carbon
monoxidepoisoning,personalinjuryordeath.
RISQUED’INDENDIEOUD’EXPLOSION
Le non-respect des avertissements de sécurité
pourraitd’entraînerdesblessuresgraves,lamort
ou des dommages matériels.
Ne jamais utiliser une flamme nue por
vérier la présence des fuites de gaz. Pour la
véricationdetouslesjoints,utiliserplutôtune
solution savonneuse commerciale fabriquée
spéciquementpurladétectiondesfuitesdegaz.
Unincendieouuneexplosionpeutentraînerdes
dommagesmatériels,desblessuresoulamort.
AVERTISSEMENT:
FIRE OR EXPLOSION HAZARD
Failuretofollowsafetywarningsexactlycould
resultinseriousinjuryorpropertydamage.
Nevertestforgasleakswithanopename.
Useacommerciallyavailablesoapsolution
madespecicallyforthedetectionofleaksto
checkallconnections.Areorexplosionmay
result causing property damage, personal
injuryorlossoflife.
WARNING: